11726-7  Circulatory system Peak systolic flow US.dopplerCirculatory system Peak systolic flow US.dopplerBlood flow.systolic.max: Vel: Pt: {Circulatory system}: Qn: US.doppler  

NAME
  Fully Specified Name: 
Component   Property   Time   System   Scale   Method
Blood flow.systolic.max  Vel  Pt  {Circulatory system}  Qn  US.doppler
  Long Common Name:  Circulatory system Peak systolic flow US.doppler
  Short Name:  Circ sys Vmax sys DOP

TERM DEFINITION/DESCRIPTION(S)
  Maximum value of the Doppler shift frequency envelope.
 
 

PART DEFINITION/DESCRIPTION(S)
  Part: US.doppler
  Doppler ultrasound detects the shift in frequency of ultrasound signals reflected from moving objects. Conventional Doppler techniques assess the velocity of blood flow by measuring high-frequency, low-amplitude signals from small, fast-moving blood cells. [PMID: 16534017]
 
 

BASIC ATTRIBUTES
  Class/Type: OB.US/Clinical
  First Released in Version: 1.0j-a
  Last Updated in Version: 2.48
  Order vs. Obs.: Observation
  Status: Active

PARTS

Part Type    Part No.  Part Name   
Component   LP76175-6  Blood flow.systolic.max 
Property   LP6888-4  Vel   [Velocity (distance/time)] 
Time   LP6960-1  Pt   [Point in time (spot)] 
System   LP76017-0  {Circulatory system} 
Scale   LP7753-9  Qn 
Method   LP6617-7  US.doppler   [Ultrasound.doppler] 
Fragments for synonyms   LP36285-2  Flow 

LANGUAGE VARIANTS
  Chinese (CHINA)  (From: Regenstrief-generated full translation based on part translation provided by Lin Zhang, A LOINC volunteer from China)
 
  血流.收缩期.最大值:速度:时间点:{循环系统}:定量型:超声.多普勒血流.收缩期.最大值:速度:时间点:{循环系统}:定量型:超声.多普勒
  Italian (ITALY)  (From: Regenstrief-generated full translation based on part translation provided by Consiglio Nazionale delle Ricerche)
 
  Flusso sanguigno.sistolico.massimo:Vel:Pt:{Apparato circolatorio}:Qn:Eco.dopplerFlusso sanguigno.sistolico.massimo:Vel:Pt:{Apparato circolatorio}:Qn:Eco.doppler
  Portuguese (BRAZIL)  (From: HL7 Brazil Institute)
 
  Fluxo sanguíneo.sistólica.máxima:Velocidade:Pt:{Sistema circulatório}:Qn:US.dopplerFluxo sanguíneo.sistólica.máxima:Velocidade:Pt:{Sistema circulatório}:Qn:US.doppler
  Spanish (ARGENTINA)  (From: Conceptum Medical Terminology Center)
 
  flujo sanguíneo.sistólico.máximo:velocidad:punto en el tiempo:{aparato circulatorio}:cuantitativo:doppler.medidoflujo sanguíneo.sistólico.máximo:velocidad:punto en el tiempo:{aparato circulatorio}:cuantitativo:doppler.medido

RELATED NAMES
  Bld flow OBSTERICAL Sonograph
  Bld flow.sys OBSTERICAL.ULTRASOUND Sonography
  Circ Obstetrical ULS
  Circ sys Obstetrics Ultrasound
  DOP Peak V max
  DUPLEX Point in time VEL max
  Dynamic QNT Velocity
  Echography Quan Vmax
  Largest Quant Vmax sys
  Max V Quantitative  
  Maximal Random  
  Maximum Sonogram  

EXAMPLE UNITS
  Unit  Source Type
  mL/s  EXAMPLE UCUM UNITS 

UNITS (INTERNAL DETAILS)
  Source Type:  EXAMPLE UCUM UNITS 
  Unit:  mL/s 

CHANGE HISTORY
  Change Type: MIN

INTERNAL FIELDS
  Detail Page Created On: 6/26/2019 7:26:16 PM
  Attachment Units Required: Y
  Long Common Name: Circulatory system Peak systolic flow US.doppler
  Shortname: Circ sys Vmax sys DOP
  Fully Specified Name: Blood flow.systolic.max: Vel: Pt: {Circulatory system}: Qn: US.doppler
     
  Component Word Count: 4
  ID: 1910
  Status (Raw): ACTIVE